Vicon SVR-W-V5-C User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 5
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
www.vicon-cctv.com
Surveyor-Mini
Specications
Operational
Preset Capability: 64 programmable.
Preset Solving
Speed:
2 seconds nominal.
Preset Accuracy
(Pan and Tilt):
0.25° maximum.
Tour Capabilities: 8 tours available. 32 programmable events
per tour. Events may be preset positions
with speed control, alarm acknowledge,
dwell time control, relay control, call autot-
ours, tour repeat or another tour, save/recall
camera status.
Autotour
Capabilities:
2 autotours available with 256 pan, tilt and
zoom functions per autotour. Programming
is done in real time with joystick and push
buttons.
Sectoring: 8 maximum, programmable for size and
titling. Sectors have the capability to be
blanked out.
Alarm
Capabilities:
1 alarm input, programmable. Functional
state enable/disable. Report state (report
on/off). Active state (high/low). Mode
(manual, momentary or automatic) with
programmable dwell time control. Set and
reset action (preset solve, relay on/off, tour,
autotour). Alarm titling.
Control Display: On-screen, menu-driven system allowing full
congurationofthedome.
Scheduling: Real-time clock allows scheduling of up to
64 events, including presets, relays, alarms,
tours or autotours.
Multi-language
Menu:
English, Spanish, French, Italian and Ger-
man.
Camera Features: Image freeze during preset solve.
Screen Titling
Capabilities:
Programmable for camera, preset, sector,
relay and alarms.
Camera: 1 for each.
Preset: 64 maximum.
Sector: 8 maximum.
Alarm: 1 maximum.
Individual type date and time enable/dis-
able; 20 characters maximum.
Selectable position.
Three text sizes for top 2 lines.
Fade capability.
Compass/azimuth, 8 compass headings (N,
NE, E, SE, S, SW, W, NW).
Auto Baud: Auto baud detection in RS-422/ RS-485
mode. 4800, 9600, 19,200 bps baud rates
supported.
Absolute Position
Control:
Available in RS-422/RS-485 mode.
Pan/tilt: 0.125°.
Zoom: 0.125X.
Environmental
Operating
Temperature
Range:
Indoor units: 32 to 104° F
(0 to 40° C).
Outdoor units: -4 to 122° F
(-20 to 50° C) continuous rotation.
Operating
Humidity Range:
Indoor: 0 to 90% relative, non-condensing.
Outdoor: 100% relative,
non-condensing.
Storage
Temperature
Range: -40 to 150° F (-40 to 65° C).
Storage
Humidity Range: 0 to 90% relative,
non-condensing.
Rain/Wind: Outdoor: heavy rain up to
4 in./hr at winds up to
90 mph, when mounted on standard Vicon
wall mount.
Page view 2